System administration/ProLiant/Remove a disk from your redundant storage array and review OS logs
Appearance
Disk Failed
[edit | edit source]journalctl -r Oct 08 20:00:12 HOSTNAME smad[3324]: WARNING: Slot 0 Smart Array - Logical drive status changed to recovering Oct 08 20:00:12 HOSTNAME smad[3324]: CRITICAL: Smart Array - Drive is failed: Port 1I Box 3 Bay 1
ssacli ctrl slot=0 pd all show status physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 480 GB): OK physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 480 GB): OK physicaldrive 1I:3:1 (port 1I:box 3:bay 1, 2 TB): Failed physicaldrive 1I:3:2 (port 1I:box 3:bay 2, 2 TB): OK physicaldrive 1I:3:3 (port 1I:box 3:bay 3, 2 TB): OK physicaldrive 1I:3:4 (port 1I:box 3:bay 4, 2 TB): OK physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 2 TB): OK physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 2 TB): OK
Disk Rebuilding
[edit | edit source]After inserting a healthy disk array will rebuild RAID:
journalctl -r Oct 08 20:10:13 HOSTNAME smad[3324]: WARNING: Slot 0 Smart Array - Logical drive status changed to rebuilding Oct 08 20:10:13 HOSTNAME smad[3324]: NOTICE: Smart Array - Drive is failed: Port 1I Box 3 Bay 1 has been repaired
ssacli ctrl slot=0 pd all show status physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 480 GB): OK physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 480 GB): OK physicaldrive 1I:3:1 (port 1I:box 3:bay 1, 2 TB): Rebuilding physicaldrive 1I:3:2 (port 1I:box 3:bay 2, 2 TB): OK physicaldrive 1I:3:3 (port 1I:box 3:bay 3, 2 TB): OK physicaldrive 1I:3:4 (port 1I:box 3:bay 4, 2 TB): OK physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 2 TB): OK physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 2 TB): OK
To track progress: ssacli ctrl slot=0 ld all show status
or ssacli ctrl slot=0 ld all show
ssacli ctrl slot=0 ld all show HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) Array A logicaldrive 1 (894.00 GB, RAID 0, OK) Array B logicaldrive 2 (9.10 TB, RAID 5, Recovering, 1.69% complete)
ssacli ctrl slot=0 ld all show status logicaldrive 1 (894.00 GB, RAID 0): OK logicaldrive 2 (9.10 TB, RAID 5): Recovering, 4.43% complete
Disk Repaired
[edit | edit source]journalctl -r Oct 08 22:12:49 hphq1 smad[3324]: NOTICE: Slot 0 Smart Array - Logical drive status changed to ok has been repaired
ssacli ctrl slot=0 pd all show status physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 480 GB): OK physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 480 GB): OK physicaldrive 1I:3:1 (port 1I:box 3:bay 1, 2 TB): OK physicaldrive 1I:3:2 (port 1I:box 3:bay 2, 2 TB): OK physicaldrive 1I:3:3 (port 1I:box 3:bay 3, 2 TB): OK physicaldrive 1I:3:4 (port 1I:box 3:bay 4, 2 TB): OK physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 2 TB): OK physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 2 TB): OK