Disk Failed[edit | edit source]

journalctl -r
Oct 08 20:00:12 HOSTNAME smad[3324]: WARNING: Slot 0 Smart Array - Logical drive status changed to recovering
Oct 08 20:00:12 HOSTNAME smad[3324]: CRITICAL:   Smart Array - Drive is failed: Port 1I Box 3 Bay 1
ssacli ctrl slot=0 pd all show status
   physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 480 GB): OK
   physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 480 GB): OK
   physicaldrive 1I:3:1 (port 1I:box 3:bay 1, 2 TB): Failed
   physicaldrive 1I:3:2 (port 1I:box 3:bay 2, 2 TB): OK
   physicaldrive 1I:3:3 (port 1I:box 3:bay 3, 2 TB): OK
   physicaldrive 1I:3:4 (port 1I:box 3:bay 4, 2 TB): OK
   physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 2 TB): OK
   physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 2 TB): OK

Disk Rebuilding[edit | edit source]

After inserting a healthy disk array will rebuild RAID:

journalctl -r
Oct 08 20:10:13 HOSTNAME smad[3324]: WARNING: Slot 0 Smart Array - Logical drive status changed to rebuilding
Oct 08 20:10:13 HOSTNAME smad[3324]: NOTICE:   Smart Array - Drive is failed: Port 1I Box 3 Bay 1 has been repaired


ssacli ctrl slot=0 pd all show status

   physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 480 GB): OK
   physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 480 GB): OK
   physicaldrive 1I:3:1 (port 1I:box 3:bay 1, 2 TB): Rebuilding
   physicaldrive 1I:3:2 (port 1I:box 3:bay 2, 2 TB): OK
   physicaldrive 1I:3:3 (port 1I:box 3:bay 3, 2 TB): OK
   physicaldrive 1I:3:4 (port 1I:box 3:bay 4, 2 TB): OK
   physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 2 TB): OK
   physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 2 TB): OK

To track progress: ssacli ctrl slot=0 ld all show status or ssacli ctrl slot=0 ld all show

 ssacli ctrl slot=0 ld all show 
HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded)
   Array A
      logicaldrive 1 (894.00 GB, RAID 0, OK)
   Array B
      logicaldrive 2 (9.10 TB, RAID 5, Recovering, 1.69% complete)
ssacli ctrl slot=0 ld all show status
   logicaldrive 1 (894.00 GB, RAID 0): OK
   logicaldrive 2 (9.10 TB, RAID 5): Recovering, 4.43% complete

Disk Repaired[edit | edit source]

journalctl -r
Oct 08 22:12:49 hphq1 smad[3324]: NOTICE: Slot 0 Smart Array - Logical drive status changed to ok has been repaired
ssacli ctrl slot=0 pd all show status
   physicaldrive 2I:3:7 (port 2I:box 3:bay 7, 480 GB): OK
   physicaldrive 2I:3:8 (port 2I:box 3:bay 8, 480 GB): OK
   physicaldrive 1I:3:1 (port 1I:box 3:bay 1, 2 TB): OK
   physicaldrive 1I:3:2 (port 1I:box 3:bay 2, 2 TB): OK
   physicaldrive 1I:3:3 (port 1I:box 3:bay 3, 2 TB): OK
   physicaldrive 1I:3:4 (port 1I:box 3:bay 4, 2 TB): OK
   physicaldrive 2I:3:5 (port 2I:box 3:bay 5, 2 TB): OK
   physicaldrive 2I:3:6 (port 2I:box 3:bay 6, 2 TB): OK