System administration/ProLiant/HPE ProLiant Smart Array Controllers
Appearance
(Redirected from Disk array controller)
HPE ProLiant Smart Array Controllers: SSACLI examples[1]
[edit | edit source]Show Controller information:
ssacli ctrl all show config
ssacli ctrl all show detail
ssacli ctrl all show status
ssacli ctrl all show status HPE Smart Array P408i-a SR Gen10 in Slot 0 (Embedded) Controller Status: OK Cache Status: OK Battery/Capacitor Status: OK
- Show logical disk status:
ssacli ctrl slot=0 ld all show status
- Rescan for new devices:
ssacli rescan
Create new RAIDs
- Create New RAID 0 Logical Drive:
ssacli ctrl slot=0 create type=ld drives=1I:1:2 raid=0
- Create New RAID 1 Logical Drive:
ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2 raid=1
- Create New RAID 5 Logical Drive:
ssacli ctrl slot=0 create type=ld drives=1I:1:1,1I:1:2,2I:1:6,2I:1:7,2I:1:8 raid=5
- Turn on Blink Physical Disk LED:
ssacli ctrl slot=0 ld 2 modify led=on
- Turn off Blink Physical Disk LED:
ssacli ctrl slot=0 ld 2 modify led=off
Activities
[edit | edit source]- Learn about different HPE Array Controllers (S-class, E-class, and P-class)
- S100i storage controller
- Learn about P-class controllers: P420i and P408i
- HPE Smart Array P408i[2] with support for
- RAID 0, 1, 5, 6, 10, 50, 60, 1 ADM, 10 ADM (Advanced Data Mirroring)
- Encryption (optional license)
- Internal: 8 SAS/SATA lanes across 2 x4 Mini-SAS ports
- HPE SmartSSD Wear Gauge reports the amount of lifetime remaining on your SSDs
- HPE Smart Array SRSmartCache (optional license)
- Expand Array, Heal Array, Move Drives, Re-Mirror Array, Shrink Array, Spare Management and Split Mirrored Array
- HPE P816i-a storage controller
- Read about HPE Smart Array SR Gen10 User Guide: https://support.hpe.com/hpsc/doc/public/display?docId=a00019059en_us and
- Read HPE Smart Array Configuration Guide: https://support.hpe.com/hpsc/doc/public/display?docId=emr_na-a00018944en_us and learn differences between HPE SSA UEFI System Utilities and HPE Smart Storage Administrator (SSA)
- Read StackOverflow questions about Smart Arrays: https://serverfault.com/questions/tagged/hp-smart-array?tab=Votes
- Understand output from: ssacli ctrl all show config